UPSTAR Mini MC Series Specifications (2kVA – 5kVA)

| Model | MC-20K | MC-30K | MC-50K | |
|---|---|---|---|---|
| Input | Voltage | 100V+15%、-10% | ||
| Frequency | 50/60Hz±5% | |||
| Required power capacity | 2.2kVA | 3.3kVA | 5.5kVA | |
| Operating method | Commercial synchronous operation, continuous inverter power supply | |||
| Output | Voltage | 100V | ||
| Frequency | 50/60Hz | |||
| Number of phases | Single-phase, two-wire | |||
| Voltage accuracy | Within ±2% | |||
| Transient voltage fluctuation | Within ±5% ※1 | |||
| Voltage waveform distortion | 3% or less (linear load), 5% or less (rectifier load ※2) | |||
| Frequency accuracy | ±0.1% during asynchronous operation | |||
| Overload capacity | 120% for 1 minute | |||
| Battery | Type | Small-sized valve-regulated lead-acid battery | ||
| Backup time (initial value at 25°C) | Approx. 10 minutes (at load power factor 0.7) | |||
| Recharge time | 12 hours | |||
| Dimensions | Width | 176mm | 245mm | |
| Depth | 530mm | 620mm | ||
| Height | 479mm | 585mm | ||
| Weight | Approx. 50kg | Approx. 60kg | Approx. 104kg | |
| General | Dielectric strength | 1500V for 1 minute | ||
| Heat dissipation | 282W | 422W | 706W | |
| Ambient temperature | 0–40°C | |||
| Relative humidity | 90% or less (no condensation) | |||
| Cooling method | Forced air cooling | |||
| Noise level | 40dB or less | |||
| Installation location | Indoor use | |||
※1 During commercial power outage ⇔ recovery, sudden load change from 0% ⇔ 100%, or sudden input voltage fluctuation of ±10%, with rectifier load at 80%
※2 Crest factor: 3.0 or less
UPSTAR Mini MC Series Specifications (7.5kVA – 10kVA)

| Model | MC-7510 | MC-10010 | |
|---|---|---|---|
| Rated output capacity | 7.5kVA | 10kVA | |
| Input | Voltage | 100V or 200V ±15% | |
| Frequency | 50/60Hz±5% | ||
| Number of phases | Single-phase, two-wire | ||
| Operating method | Commercial synchronous, continuous inverter power supply | ||
| Output | Voltage | 100V or 200V | |
| Frequency | 50/60Hz | ||
| Number of phases | Single-phase two-wire or single-phase three-wire | ||
| Voltage accuracy | ±2% | ||
| Transient voltage fluctuation | Within ±5% | ||
| Voltage waveform distortion | 3% or less (linear load), 7% or less (rectifier load) | ||
| Frequency accuracy | ±0.1% during asynchronous operation (Synchronization range adjustable to ±1–3%) | ||
| Overload capacity | 120% for 1 minute | ||
| Battery | Type | Small-sized valve-regulated lead-acid battery | |
| Backup time | 10 minutes | ||
| (initial value at 25°C) | |||
| Recharge time | Approx. 12 hours | ||
| Dimensions | Width | 350mm | |
| Depth | 750mm+80mm | ||
| Height | 930mm | ||
| Weight | Approx. 275kg ※1 | Approx. 325kg ※2 | |
| General | Ambient temperature | 0–40°C | |
| Relative humidity | 30–90% (no condensation) | ||
| Cooling method | Forced air cooling | ||
| Noise level | 50dB or less | ||
| Installation location | Indoor use | ||
※1 Approx. 320kg with 100V input
※2 Approx. 375kg with 100V input
For three-phase input models, please contact us by email or phone.