UPS

Uninterruptible AC Power Supply

UPS

In the event of power disturbances such as unexpected power outages or momentary voltage drops, the system continues supplying power for a certain period of time, protecting critical equipment and data from failure or loss.

Features

  • High-frequency PWM control using IGBT inverters enables instantaneous response to rapidly fluctuating loads, supplying safe and highly efficient power.
  • Commercial power synchronized operation allows seamless transfer to the commercial power supply circuit during overloads or failures, ensuring uninterrupted power supply to the load.
  • Supports various battery types and cell counts for DC 100V input systems
    (e.g., 54-cell lead-acid batteries, 86-cell alkaline batteries, and others).
  • Compatible with systems equipped with DC 100V direct current loads.
  • Complies with the Japan Sewage Works Agency specifications
    (“General Specifications for Electrical Equipment Constru ction”).

Installation Conditions

SeriesVNS Series
Rated output1kVA3kVA5kVA7.5kVA10kVA15kVA20kVA
Operating methodContinuous inverter supply system
Control methodPWM control method
Cooling methodNatural coolingForced air cooling
AC InputNumber of phasesSingle-phase or three-phase
Rated voltage100V, 200V, 400V
Rated frequency50Hz or 60Hz
DC InputRated voltage120V (for MSE-type lead-acid battery, 54-cell configuration)
Voltage range90V~140V
AC OutputNumber of phasesSingle-phase, two-wire system
Rated voltage100V or 105V
Adjustment rangeWithin ±5%
Voltage accuracyWithin ±2%
Rated frequency50Hz or 60Hz
Frequency accuracyWithin ±0.1% (asynchronous operation)
Frequency synchronization rangeWithin ±1Hz
Rated load power factorLagging 0.8 (0.7–0.9)
Voltage waveform distortion5% or less (linear load)
Instantaneous voltage fluctuation±10% or less (load change 0% ⇔ 100%)
Settling timeWithin 100ms (load change 0% ⇔ 100%)
Inverter efficiency80% or higher
Transfer timeNo interruption (synchronized operation)
Auto retransfer (auto bypass)Bypass transfer at 110% (r.m.s) or higher (synchronized)
Inverter transfer at 102% (r.m.s) or lower (synchronized)
Overload capacity120% for 5 minutes
150% for 10 seconds (asynchronous operation)

Specifications

Ambient temperature0–40°C
Relative humidity30–90%
Noise level65 dB or less (A-weighted) for 1–7.5kVA
75 dB or less (A-weighted) for 10–20kVA
Installation environmentLocations free from dust and corrosive gases
Paint colorMunsell 5Y7/1, semi-gloss ※Color can be changed upon request.
DC load connectionDC 100V connection available

DC Side

Lead-Acid Batteries
MSE, MSJ, UP
Number of cells54 cells
Float voltage120V(MSE,MSJ,UP)
End-of-discharge voltage90V
Alkaline storage battery
AHH-P
Number of cells 86 cells
Float voltage123V(AMH-PE)
Equalizing voltage140V(AMH-PE)
End-of-discharge voltage90V

Applicable Standards

  • Japanese Industrial Standards (JIS)
  • Electrotechnical Committee Standards (JEC)
  • Japan Electrical Manufacturers’ Association Standards (JEM)
  • Storage Battery Association Standards (SBA)
  • Other specifications for water and sewage facilities are supported as required.

Battery capacity is selected according to the presence of DC loads and the required backup time.
Design customization is available to meet installation conditions and on-site requirements.

Basic Product Knowledge