UPS

Uninterruptible Power Supply (UPS) Apster Mini MC Series

UPS

Provides backup power for OA, FA, and SA applications, protecting against power disturbances such as momentary voltage drops and power outages. It is also effective as a countermeasure against power outages anticipated due to electricity shortages.

UPSTAR Mini MC Series Specifications (2kVA – 5kVA)

ModelMC-20KMC-30KMC-50K
InputVoltage100V+15%、-10%
Frequency50/60Hz±5%
Required power capacity2.2kVA3.3kVA5.5kVA
Operating methodCommercial synchronous operation, continuous inverter power supply
OutputVoltage100V
Frequency50/60Hz
Number of phasesSingle-phase, two-wire
Voltage accuracyWithin ±2%
Transient voltage fluctuationWithin ±5% ※1
Voltage waveform distortion3% or less (linear load), 5% or less (rectifier load ※2)
Frequency accuracy ±0.1% during asynchronous operation
Overload capacity120% for 1 minute
BatteryTypeSmall-sized valve-regulated lead-acid battery
Backup time
(initial value at 25°C)
Approx. 10 minutes (at load power factor 0.7)
Recharge time12 hours
DimensionsWidth176mm245mm
Depth530mm620mm
Height479mm585mm
WeightApprox. 50kgApprox. 60kgApprox. 104kg
GeneralDielectric strength1500V for 1 minute
Heat dissipation282W422W706W
Ambient temperature0–40°C
Relative humidity90% or less (no condensation)
Cooling methodForced air cooling
Noise level40dB or less
Installation locationIndoor use

※1 During commercial power outage ⇔ recovery, sudden load change from 0% ⇔ 100%, or sudden input voltage fluctuation of ±10%, with rectifier load at 80%
※2 Crest factor: 3.0 or less

UPSTAR Mini MC Series Specifications (7.5kVA – 10kVA)

ModelMC-7510MC-10010
Rated output capacity7.5kVA10kVA
InputVoltage100V or 200V ±15%
Frequency50/60Hz±5%
Number of phasesSingle-phase, two-wire
Operating methodCommercial synchronous, continuous inverter power supply
OutputVoltage100V or 200V
Frequency50/60Hz
Number of phasesSingle-phase two-wire or single-phase three-wire
Voltage accuracy±2%
Transient voltage fluctuationWithin ±5%
Voltage waveform distortion3% or less (linear load), 7% or less (rectifier load)
Frequency accuracy±0.1% during asynchronous operation
(Synchronization range adjustable to ±1–3%)
Overload capacity120% for 1 minute
BatteryTypeSmall-sized valve-regulated lead-acid battery
Backup time10 minutes
(initial value at 25°C)
Recharge timeApprox. 12 hours
DimensionsWidth350mm
Depth750mm+80mm
Height930mm
WeightApprox. 275kg ※1Approx. 325kg ※2
GeneralAmbient temperature0–40°C
Relative humidity30–90% (no condensation)
Cooling methodForced air cooling
Noise level50dB or less
Installation locationIndoor use

※1 Approx. 320kg with 100V input
※2 Approx. 375kg with 100V input
For three-phase input models, please contact us by email or phone.